Ventilation & Eciency
Ventilation
EcoSmart Fires do not require any form of permanent xture or tting,
such as a ue for ventilation, a permanent connection or any kind of
xed utility for fuel supply.
Do not cover any existing ventilation systems or structures that are
built or installed within the chosen installation area.
To ensure adequate ventilation, make sure to follow the guidelines in
the table shown.
Underwriters Laboratories calculates adequate air exchange as follows:
In a house of typical construction, that is, one that is not of unusually
tight construction due to heavy insulation and tight seals against air
inltration, an adequate supply of air for combustion and ventilation is
provided through inltration. However, if the Burner is used in a small
room where less than 5.7m
3
[200ft
3
] of air space is provided for each
1000 BTU per hour of appliance rating (considering the maximum Burner
setting), the door(s) to adjacent room(s) should be kept open or a window
to the outside should be opened at least 25.4mm [1in] to guard against
potential build up of indoor air pollution. Do not install or operate in a
bathroom or any other small room.
The ventilation requirements must always be met. The burner must only
be installed in areas that are protected from the draft eects of cross
ventilation.
Model Minimum room size
BK5
The room cannot be less than 70m
3
[2472ft
3
] per burner.
BK3
The room cannot be less than 45m
3
[1589ft
3
] per burner.
BK2UL
The room cannot be less than 45m
3
[1589ft
3
] per burner.
XL900
The room cannot be less than 110m
3
[3884ft
3
] per burner.
XL700
The room cannot be less than 90m
3
[3178ft
3
] per burner.
XL500
The room cannot be less than 80m
3
[2825ft
3
] per burner.
XS340
The room cannot be less than 45m
3
[1589ft
3
] per burner.
VB2
The room cannot be less than 45m
3
[1589ft
3
] per burner.
AB8
The room cannot be less than 105m
3
[3708ft
3
] per burner.
AB3
The room cannot be less than 40m
3
[1413ft
3
] per burner.