INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS
ECOSOFT ROBUST 1000, ROBUST 1500, ROBUST PRO, ROBUST 3000
Recovery has decreased
signicantly
Clogged pre-lter Replace pre-lter
Clogged membranes Replace membranes
Water is not discharged to
drain when the system is on
Clogged ow restrictor Clean ow restrictor or re-
place if necessary
Puried water is hazy or
cloudy but becomes clear
aer a few minutes
Air bubbles trapped in the
system
Some air may remain in the
system for a few days aer
installaon and will go away
on its own.
Air bubbles may appear in
water if there is a large dier-
ence between feed water and
ambient temperature
Puried water has a taste or
odor
Expired post-lter Replace post-lter
Membrane preservave was
not ushed fully aer the
installaon
Flush the RO system and
discard all rinse water
Contaminaon of the system Sanize the system according
to instrucons in p. 7
Contaminaon of pressure
tank
Sanize pressure tank.
Pressure tank may become
contaminated if lters or
membranes are used beyond
their service life
Pressure tank is not full when
the system switches o
Tank bladder is overinated Pressure in empty tank
bladder must be 0.6–1.0 atm.
Release some pressure if
necessary.
Operaon is performed by
water lter service specialist
Tank valve is closed Check tank valve posion