Step 3
If you have recently taken a Chiller Hose
off of the Chiller or Tub (For example, to
clean the Inner Water Strainer), it is
possible that an air lock can be created
within the Chiller. We will want to
release this air lock in the system by
loosening the Lower Water Filter
Housing. Loosen the housing until it is
completely off, fill up with water to the
top, and reinstall.
If the steps above do not resolve the
problem, please contact
support@edgetheorylabs.com so that
we can further assist you!
Air Trapped in Unit
There is a Check Valve inside the outlet
port on the Chiller. This can become
stuck in the closed position and prevent
water from flowing through the unit. If
you notice that the Chiller is trying to
prime but no bubbles are coming out
from the Tub Water-In Fitting, this is a
possible resolution. You will first close
the Tub Fitting Valves by rotating to the
Closed (perpendicular) position to the
Valve body.
Then Remove the Outlet Chiller Hose
and check to see if the little pin in the
valve is stuck outward (toward you). If it
is stuck outward, use a small
screwdriver and press on it gently. If it
was indeed stuck, you will feel and/or
hear a little click that indicates the
Check Valve has returned to position.
Reinstall the Chiller Hose, open the Tub
Fitting Valves, and try Chiller again.
Step Two
Check Valve (Outlet Port)
Step 2- reference
Step 1- reference