9.3 Error codes and solutions
1. Check whether the terminals CN3 and CN5 are secure,
pull out the terminal and replace it if necessary.
2. Check to see if there is foreign matter on the terminal.
3. Inspect the temperature sensor and test its
resistance. (See 10.3 & 10.8)
4. Replace main control board.
1. Check whether the terminal CN3 and CN5 are secure,
pull out the terminal and replace it if necessary.
2. Check to see if there is foreign matter on the terminal.
3. Inspect the frost sensor check whether contact is bad.
4. Replace main control board
9.4 Defrost function
The defrosting of the evaporator is activated when the temperature monitored by defrost sensor is below
set point. The compressor switches off, and following a temperature rise, the frost on evaporator
becomes water. The water flows into the water pan via the drain system and will eventually evaporate.