8
Notes:
• Choose a location that has ambient temperatures above 50° F and below 90° F.
Operationoutsidethesetemperaturesmayresultinloweredeciencyorcauseother
adverseeects.
• This unit MUST be installed in an area protected from the elements, e.g. wind, rain,
water spray or drips.
• The refrigerator should not be located next to ovens, grills, or other heat sources.
• Do not kink or pinch the power supply cord between the commercial refrigerator and the
wall or cabinet.
Clearance Requirements
Top View:
When installing the commercial refrigerator with a built-in installation, follow the recommended
spacing dimensions shown.
To ensure proper service access and ventilation, allow at least 3/4” of clearance at the back, 1/2” at
the top, and 1/2” at the sides. If the door side is against a wall, allow at least 1 13/16” of clearance.
The installation should allow the unit to be pulled forward for servicing, if necessary.
1/2”
3/4”