MMU-16LE SmartMonitor
Operations Manual
Eberle Design Inc. Page 6
1.4.2.2 FORCE TYPE 16 MODE
If the cabinet is already wired for 16 channel operation but the TYPE SELECT input is not
accessible due to cabinet wiring issues, the MMU-16LE SmartMonitor
®
can be forced to the
Type 16 mode by setting the FORCE TYPE 16 option in Unit Options. See Section 6.3.4.8.
The FORCE TYPE 16 mode is not compatible with the TYPE 12 WITH SDLC mode
(section 1.4.2.1).