2 / 6 P/N 270482 • REV 06 • REB 18JAN13
Figure 3: Cover installation
Note: 3-ASU/4 chassis shown.
Figure 4: Installation complete
Note: 3-ASU/4 chassis shown.
Wiring
Wire the 3-ASU and 3-ASU/4 as shown in Figure 5, Figure 6,
and Figure 7.
Notes
• All wiring is supervised and power-limited.
• If a 3-RS485 card is not installed, connect AUDIO DATA
PRIMARY on the ASU card to AUDIO A OUT on the
3-CPUx card. See Figure 5.
If a 3-RS485 card is installed, connect AUDIO DATA
PRIMARY on the ASU card to AUDIO A IN on the 3-CPUx
card.
• Wiring from a 3-REMICA or 3-REMICP must be shielded
and enclosed in conduit. See Figure 5.
• All shields must be continuous and insulated from ground,
except at the originating panel.
• The REMOTE input is for MNEC applications only. Not for
supplemental use.
Figure 5: ASU card wiring diagram