Earthing
The earthing cable connected to the pump (PE) should be minimum 10 mm
2
(according to EN 60204-1
section 828).
Cable sizing according IEC
The tables below indicate the current carrying capacities of cables for 3 commonly used installation
methods, calculated according to standard 60364-5-52 - electrical installations of buildings part 5 -
selection and erection equipment and section 52 - current carrying capacities in wiring systems.
The allowed currents are valid for PVC insulated cables with three loaded copper conductors (maximum
conductor temperature 70 °C).
Installation method B2 according table
B.52.1.
Multi-core cable in conduit on a wooden
wall.
Maximum allowed current in function of the ambient temperature for installation method B2
Installation method C according table
B.52.1.
Single-core or multi-core cable on a wooden
wall