B722-40-880 Issue F
Page 32 © Edwards Limited 2013. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Installation
Table 16 - Command abbreviations
Abbreviation Meaning
cr carriage return character
chars characters
d decimal ASCII character
Note: Fields showing multiple d characters are to indicate typical length. All
data fields have a maximum of 5 decimal characters (prefixed by a minus
number for negative numbers).
h hexadecimal ASCII character
r Returned error code - refer to Table 17
sp space character
string may have several ASCII characters
X Multi-drop decimal ASCII character
Note: Fields showing multiple X characters are to indicate maximum length and
not fixed length.
Table 17 - Error codes
Returned error code Meaning
0 No error
1 Invalid command for object ID
2 Invalid Query/Command
3Missing parameter
4 Parameter out of range
5 Invalid command in current state - e.g. serial command to start/stop when in
parallel control mode