Table 15
Electrical data (three-phase pumps with Part Numbers ending in -905)
Pump
Nominal
supply
(V)
Frequency
(Hz)
Power
(W)
Full load
current
(A)
Start-up
current
(A)
Recommended
supply protecon*
(A)
RV3 and
RV5
200-220 50 250 1.7 10.2 2.5
200-230 60 300 1.7 10.2 2.5
380-415 50 250 1.0 5.7 2.5
460 60 300 1.0 7.0 2.5
RV8 and
RV12
200-208 50 450 2.5 14.0 4.0
200-230 60 550 2.9 12.0 4.0
380-415 50 450 1.5 9.0 2.5
460 60 550 1.5 8.7 2.5
* Observe requirements of local and regional electrical codes with respect to supply protecon.