Design and specifications
Page 51
2.2 Connections of the EFOY fuel cell
1
Exhaust gas hose connection with
protective cap
2
Fuel cartridge connection
3
Charging cable connection
4
Power connection for optional
accessories
5
Retainer for protective cap/factory
defaults
6
On/off/reset button
7
Ethernet connection (RJ-45 port)
8
Accessory connection (RJ-12 port)
9
Connection for exhaust heat diversion
10
Device type, serial number and MAC
address
11
Status LED
2.3 Specifications
2.3.1 12 V performance data
1
EFOY 80
EFOY 150
EFOY Pro
900
EFOY Pro
1800
EFOY Pro
2800
Max. output power
40 W
75 W
42 W
82 W
125 W
Output power
2
after 3,000
operating hours
24 W 45 W 34 W 68 W 105 W
Output power
2
after 6,000
operating hours
---
3
---
3
28 W 56 W 87 W
Max. charging current at
10.5 V
3.8 A 7.1 A 4.0 A 7.8 A 11.9 A
Recommended minimum
battery capacity of lead
batteries
40 Ah 60 Ah 40 Ah 60 Ah 80 Ah
Maximum settable battery
capacity of lead batteries
800 Ah

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EFOY 80 and is the answer not in the manual?

EFOY 80 Specifications

General IconGeneral
TechnologyDirect Methanol Fuel Cell (DMFC)
FuelMethanol
Nominal voltage12 V
Operating voltage10.5 V - 15 V
Operating temperature+40 °C

Related product manuals