Reset Memory: Hold down the test button until the red light stops and the green
light starts flashing. Cover the horn with a cloth to muffle the alarm during this time.
Please note that the memory will also be reset when the CO Alarm is switched off.
3. Where to place CO Alarms
3.1 Ideally a Carbon Monoxide Alarm should be installed in:
- Every room containing a fuel burning appliance, and
- Remote rooms where occupants spend a considerable amount of time
- Every bedroom
However if the number of Carbon Monoxide Alarms to be fitted is limited, the
IROORZLQJSRLQWVVKRXOGEHFRQVLGHUHGZKHQGHFLGLQJZKHUHEHVWWRILWWKHDODUPV
- If there is an appliance in a room where people sleep, place a CO Alarm in
this room
- Locate a CO Alarm in a room containing a flueless or open-flued appliance, and
/RFDWHDQ$ODUPLQDURRPZKHUHWKHRFFXSDQWVVSHQGPRVWRIWKHLUWLPHHJ
VLWWLQJURRP
Table C: CO Alarm Memory Indicators
CO Gas Level
ppm > 43 ppm
2 flashes every minute (approx)
ppm > 80 ppm
4 flashes every minute (approx)
ppm > 150 ppm
8 flashes every minute (approx)
Red Light Response
24 Hours
On Demand (Button Press)
2 flashes
4 flashes
8 flashes
10

Other manuals for Ei Electronics Ei207 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ei Electronics Ei207 Series and is the answer not in the manual?

Ei Electronics Ei207 Series Specifications

General IconGeneral
BrandEi Electronics
ModelEi207 Series
CategorySecurity System
LanguageEnglish

Related product manuals