12. TECHNICAL SPECIFICATIONS
Operating Voltage : 230±10% VAC, 50Hz
Power : 1 Watt (90 mA)
Power on Indicator : Green Light
Sensor : Electrochemical Sensor
CO Sensitivity : Meets BS EN 50291: 2001.
Unit operates as per Table B.
Apparatus Type : Apparatus Type A
Conformance to
Standards : 3rd Party tested & Kitemarked to BS EN 50291:2001 by BSI
Electrical Safety : Complies with relevant sections of EN 60335-1: 1994
Electromagnetic : Complies with BS EN 50270 including requirements of
the R&TTE Directive
Compatibility : Compatibility 1999/5/EC (RF Performance to EN300220-3,
EMC to EN50270) - independently tested
Test/Hush Button : Checks electronics and horn.
When the Alarm is sounding, after sensing CO, pressing the Test/Hush button will immediately stop
the horn (the red alarm light will continue to flash). If CO is still present the red alarm light and the
horn will turn on again after about 4 minutes. The Alarm can only be silenced once during a CO
incident. At 300 ppm CO the Alarm cannot be silenced. (With interconnected units, the Hush only
works on the alarm sensing CO).