EasyManuals Logo

Ei Electronics Ei600 Series Instructions

Ei Electronics Ei600 Series
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
On a Sloping Ceiling
With a sloping or peaked ceiling install a Smoke Alarm within 600mm of the peak or
a Heat Alarm within 150mm of the peak (measured vertically). If this height is less
than 600mm for Smoke Alarms or 150mm for Heat Alarms the ceiling is regarded
as being flat
(see Figure 4).
Locations to avoid
DON’T place Smoke Alarms in any of the following areas:
%DWKURRPV NLWFKHQVVKRZHU URRPVJDUDJHVRU RWKHUURRPV ZKHUH WKHVPRNH
alarm may be triggered by steam, condensation, normal smoke or fumes. Keep
at least 6 metres away from sources of normal smoke/fumes.
/RFDWHDZD\IURPYHU\GXVW\RUGLUW\DUHDVDVGXVWEXLOGXSLQWKHFKDPEHUFDQLPSDLU
performance. It can also block the insect screen mesh and prevent smoke from
entering the smoke detector chamber.
DEAD AIR
SU
RFA
C
E
S
NEVER WITHIN
0
.
3
M
F ANY
RNER
IDEAL IN
C
ENTRE
O
F
C
EILIN
G
S
M
O
KE ALARM
S
<600
m
m
HEAT ALARM
S
<
15
0
m
m
APEX
x
x
Figure 3
Figure 4
11

Other manuals for Ei Electronics Ei600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ei Electronics Ei600 Series and is the answer not in the manual?

Ei Electronics Ei600 Series Specifications

General IconGeneral
BrandEi Electronics
ModelEi600 Series
CategorySmoke Alarm
LanguageEnglish

Related product manuals