It is important to check that all Alarms are communicating in their final installed
positions. If Alarms are rotated, have had their antennas extended and/or re-sited,
we would recommend that all the Alarms are returned to the factory settings and
then House Coded again in their final positions (see above). The RadioLINK
+
interconnection should then be checked again by button testing all units.
(Note: The RadioLINK
+
module can be returned to the originally factory settings by
pressing and holding the House Code switch until the blue light flashes and then releasing.
This will take about 7 seconds. This clears the House Codes that have been learnt).
Supply Voltage: 3V internal lithium battery (non-replaceable)
RF Range: A minimum of 100 metres in free space
RF Visual Indicator: Blue light flashes continuously for 0.5 to 3.5 seconds while
transmitting RF signal
RF Frequency: 868.499MHz (1% duty cycle)
Max RF Power: +10dBm
Dimensions: 57mm length x 30mm depth x 18mm height
Temperature Range: 0° to 40°C
Humidity Range: 15% to 95% Relative Humidity (non-condensing)
Interconnect *: Up to 12 RadioLINK
+
or RadioLINK modules
16
Technical Specifications