Interconnected Alarms do not all sound
Hold the Test button for at least 10 seconds to ensure that the signal is transmitted to all the
interconnected Alarms.
Check that all Alarms in the RF system are powered and are house-coded correctly. (see the
Ei600MRF RadioLINK+ module manual)
Pressing the button during an alarm does not silence the Alarm
Always make sure that you are pressing the button on the Alarm that sounds with the red LED
flashing.
Your Alarm chirps / beeps / flashes
In standby mode, the Alarm does not sound, beep, chirp or flash.
The Alarm automatically monitors the battery, sensor, electronics and piezo periodically to ensure
that all are satisfactory. If a fault has been found, the Alarm alerts the occupier to this via short
chirps and its yellow LED fault indicator flashes every 48 seconds. The Alarm will also indicate any
faults when the Test button is pressed.
See section 4.1 - Indicator Summary Tables