9. TROUBLESHOOTING
Problem Cause Solution
The compressor does not start 1. No supply voltage 1. Check the supply voltage, the power
plug and the socket-outlet.
2. Insucient supply voltage 2. Make sure that the extension cable is
not too long. Use an extension cable with
wires that are large enough to support
the required voltage.
3. Outside temperature is too low 3. Never operate with an outside
temperature of below +5°C.
4. Motor is overheated 4. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
The compressor starts but there is
no pressure
1. Leak in the non-return valve 1. Replace the non-return valve
2. The seals are damaged. 2. Check the seals and have any damaged
seals replaced by a service center
3. The drainage valve for
condensation water (11) leaks.
3. Tighten the screw by hand. Check
the seal on the screw and replace if
necessary.
The compressor starts, pressure is
shown on the pressure gauge, but
the tools do not start.
1. Loose hose connections 1. Check the compressed air hose and
tools and replace if necessary.
2. Leak in a quick-lock coupling 2. Check the quick-lock coupling and
replace if necessary.
3. Insucient pressure set on the
pressure regulator.
3. Open the pressure regulator further.