PUMP SPECIFICATIONS:
Model EK-DCP 2.2 EK-DCP 2.6 EK-DCP 4.0
Rated voltage DC12V +/-10% DC12V +/-10% DC12V +/-10%
Starting voltage DC 8V above DC 8V above DC 8V above
Power Consumption 6.5W +/-10% 8W +/-10% 18W +/-10%
Load current 0.62A +/-10% 1A +/-10% 1.8A +/-10%
Q-max 400 L/hr +/-10% 600L/hour +/-10% 800L/hour +/-10%
H-max. 2.2m +/-10% 2.6m +/-10% 4m +/-10%
Size 52 x 45 x 50mm 61.7x 46.7 x 59.7mm 75 x 54 x 66mm
life Expectancy 50000/hrs at 25° 50000/hrs at 25° 50000/hrs at 25°
Noise 17.2 dB 21.5 dB 24.5 dB
Output Signal
Wire No. Item Standard Wire Color
1
GND Black
2 Vcc 12VDC(10.8〜13.2VDC) Red
3 Sensor Square wave signal Yellow
If pump use the power cables are two wires that is only GND and Vcc without
sensor, also without signal output from the pump.
2