Voltage | 12V DC |
---|---|
Reservoir Volume | 100 ml |
Liquid Temperature Range | 0 to 60 °C |
PWM duty cycle | 20% - 100% |
Noise Level | 30 dB |
Connector | 4-pin PWM |
Material | Acetal |
Install the EK-SPC Series pump onto the pump main motor housing, ensuring the original O-ring gasket is reused.
Secure the XRES SPC using enclosed M4-M4 SPC Screws and a 2mm Allen key, avoiding over-tightening.
Screw two brackets together using enclosed M4 x 4 mm screws for the spider mount assembly.
Mount the bracket to a 120mm fan, radiator, or chassis using various screw options provided.
Screw vibration dampers onto custom SPC screws and drill four 4.2mm holes in a 50x50mm pattern.
Use enclosed M4x4mm screws to secure the pump assembly to the drilled mounting holes on the chassis.
Correctly identify and use the 'OUT' (pressure) and 'IN' (suction) ports for proper fluid flow.
Use EK-ACF fittings or ensure G1/4 thread fittings are no longer than 6 mm.
The unit must be mounted vertically; upside-down mounting risks pump damage.
Connect the 4-pin RGB LED connector to the motherboard RGB header, observing the +12V GRB pinout.