EasyManua.ls Logo

Elation SNIPER 2R - Fixture Installation

Elation SNIPER 2R
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.elationlighting.com
20 SNIPER 2RUser Manual ver 3
FIXTURE INSTALLATION
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 ft. (1.5m) away from any
flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all
electrical connections and/or installations.
CAUTIONS
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Max ambient operating temperature for this fixture is 104°F. (40°C)
Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture. (210 lbs / 95 kg)
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
POWER LINKING
Max number of units that can be power linked is 7 units @120V / 14 units @230V.
WARNING
MINIMUM distance to lighted objects must be 16.5 feet (5m)
MAXIMUM temperature of external surface 194° F (90° C)
MINIMUM distance of inflammable materials from surface 1.6 feet (0.5m)
Keep fixture at least 5.0 feet (1.5m) away from any flammable
materials, decorations, pyrotechnics, etc.