10
Product description
ErP data for THISION S PLUS
Type THISION S PLUS 13 19 24 34 35L 46 54
ErP data according to 2010/30/EU
Seasonalroom-heatingenergyeciencyclass A A A A A A A
Nominal heat output P
n
(kW) 14 18 22 34 34 45 53
Annual energy consumption Q
HE
(GJ) 5 6 7 11 10 15 17
Seasonalroom-heatingenergyeciencyclass η
s
(%) 94 94 94 94 94 94 94
Noise output level, inside L
WA
(dB) 39 43 46 50 50 51 51
Temperature regulator QAA 55 + AQC 34
Temperature regulation class Class VI VI VI VI VI VI VI
Contribution of the temperature regulation % 4 4 4 4 4 4 4
Package Boiler with Temperature regulator QAA 55 + AQC 34
Seasonalenergyeciencyofpackageforroomheating% 98 98 98 98 98 98 98
Seasonalenergyeciencyclassofpackageforroomheating A+ A+ A+ A+ A+ A+ A+
+
=
Type THISION S PLUS Combi 24 Combi 34
ErP data according to 2010/30/EU
Indicatedloadprole XL XL
Seasonalroom-heatingenergyeciencyclass A A
Energyeciencyclassofwarmwaterprovision A A
Nominal heat output P
n
(kW) 22 34
Annual energy consumption Q
HE
(GJ) 7 11
Annual energy consumption AEC (kWh) 82 93
Annual fuel consumption AFC (GJ) 23 23
Seasonalroom-heatingenergyeciencyclass η
s
(%) 94 94
Energyeciencyclassofwarmwaterprovision η
WH
(%) 80 80
Noise output level, inside L
WA
(dB) 47 50
Temperature regulator QAA 55 + AQC 34
Temperature regulation class Class VI VI
Contribution of the temperature regulation % 4 4
Package Boiler with Temperature regulator QAA 55 + AQC 34
Seasonalroomheatingenergyeciencyofpackage% 98 98
Seasonalroomheatingenergyeciencyclassofpackage A+ A+
Energyeciencyclassofwarmwaterprovisionbypackage A A
+
=
ErP data for THISION S PLUS Combi