48
Parameters technician
Menu Line no. Selection possibilities Unit Min. Max Factory setting
Diagnose User 8700 Outside temp °C -50 50
Indication only
8701 Outside temp min °C -50 50
8702 Outside temp max °C -50 50
8703 Outside temp attenuated °C -50 50
8704 Outside temp composite °C -50 50
8730 Heating circuit pump 1 - Uit, Aan
8731 Heat circ mix valve 1 open - Uit, Aan
8732 Heat circ mix valve 1 close - Uit, Aan
8735 Speed heating circuit pump 1 % 0 100
8740 Room temp 1
°C 0 50
8741 Room setpoint 1
°C 4 35
8743 Flow temp 1 °C
0 140
8744 Flow temp setpoint 1 °C
0 140
8749 Room thermostat 1 -
No demand, demand
8760 Heating circuit pump 2 -
O,On
8761 Heat circ mix valve 2 open -
O,On
8762 Heat circ mix valve 2 close -
O,On
8765 Speed heating circuit pump 2 %
0 100
8770 Room temp 2 °C
0 50
8771 Room setpoint 2 °C
4 35
8773 Flow temp 2 °C
0 140
8774 Flow temp setpoint 2 °C
0 140
8779 Room thermostat 2 - No demand, demand
8790 Heating circuit pump 3 -
O,On
8791 Heat circ mix valve 3 open -
O,On
8792 Heat circ mix valve 3 close -
O,On
8795 Speed heating circuit pump 3 %
0 100
8800 Room temp 3 °C
0 50
8801 Room setpoint 3 °C
4 35
8803 Flow temp 3 °C
0 140
8804 Flow temp setpoint 3 °C 0 140
8809 Room thermostat 3 -
No demand, demand
8820 DHW pump -
O,On
8825 Speed DHW pump %
0 100
8826 Speed DHW interm circ pump % 0 100
8827 Speed inst DHW heater pump % 0 100
8830 DHW temp 1 °C 0 140
8831 DHW temp setpoint °C 8 80
8832 DHW temp 2 °C 0 140
8835 DHW circulation temp °C 0 140
8836 DHW charging temp °C 0 140
8852 DHW consumption temp °C 0 140
8853 Instant WH setpoint °C 0 140
8860 DHWow l/min 0 30
8875 Flow temp setpoint VK1 °C 5 130
8885 Flow temp setpoint VK2 °C 5 130
8895 Flow temp setpoint VK3 °C 5 130
8900 Swimming pool temp °C 0 140
8901 Swimming pool setpoint °C 8 80
8930 Primary controller temp °C 0 140
8931 Primary controller setpoint °C 0 140
8950 Commonowtemp °C 0 140
8951 Commonowtempsetpoint °C 0 140
8952 Common return temp °C 0 140