W
woodmarieAug 8, 2025
What to do if the elco Burner starts, the ignition switches on, then failure?
- CCharles BrownAug 8, 2025
If the Elco burner starts but fails after ignition, consider these potential causes and solutions: * Incorrect gas throughput: Adjust the gas flow. * Flame monitoring malfunction: Check the condition and position of the ionization probe, and inspect the connections of the ionization circuit. * Incorrect polarization: Ensure the 7P connector's polarization is correct. * No ignition sparks: Adjust, clean, or replace the electrodes; connect or replace the ignition cables; replace the igniter. * Defective components: Replace the control unit or the compact gas unit; replace the valves if they are jamming. * Check the cabling between the control unit and external components.