Questions and Answers

  • J
    John IrwinAug 12, 2025
    Why elco VG 1.55 Burner does not start with normal gas pressure?
    • J
      john17Aug 12, 2025
      If the Elco Burner does not start, but you have normal gas pressure, it might be due to insufficient gas pressure or a gas pressostat that is wrongly set or defective. To resolve this, check the gas lines, clean the filter, and inspect or replace the gas pressostat or the compact gas unit.
  • W
    Wesley GrantAug 18, 2025
    What to do if the Elco Burner switches off during operation?
    • M
      Michelle MorganAug 18, 2025
      If the Elco Burner switches off during operation, it could be due to the air pressure switch contact opening during start-up or operation, or a flame failure during operation. You should adjust or replace the pressure switch and check the ionization sensor circuit. Also, check or replace the automatic combustion control unit.
  • D
    David BrownAug 22, 2025
    Why elco VG 1.55 Burner does not start after thermostat shutdown?
    • S
      Steven ZhangAug 22, 2025
      If the Elco Burner does not start after thermostat shutdown and there's no malfunction indicated on the automatic combustion control unit, it could be due to a drop in supply voltage, a power failure, or a control unit malfunction. Check the cause of the voltage drop or power failure and replace the control unit.
  • M
    Monica HowardAug 27, 2025
    Why Elco Burner blower starts up but burner doesn't?
    • A
      alison61Aug 27, 2025
      If the Elco Burner blower starts up, but the burner does not start, it could be because the air pressure switch contact does not close. Inspect the pressure transmitter for foreign bodies and check the wiring.
  • M
    Monique AdamsSep 1, 2025
    What to do if elco VG 1.55 starts briefly then switches off?
    • K
      kimberly51Sep 1, 2025
      If the Elco Burner starts briefly when switched on, then switches off and the red LED lights up, it means the control unit was deliberately shut down. Unlock the unit.
  • J
    James RoweNov 6, 2025
    What to do if the elco VG 1.55 starts, the ignition switches on, then failure?
    • J
      Joshua YoungNov 6, 2025
      If the Elco Burner starts, the ignition switches on, but then there's a failure, it could be due to several reasons, including no flame at the end of the safety period, incorrect gas throughput, a faulty flame monitoring circuit, no ignition arc, short-circuited electrode(s), damaged ignition cable, a defective ignition transformer or automatic combustion control unit, solenoid valves that don't open, or valves jamming. To address this, adjust the gas throughput. Inspect the condition and position of the ionization sensor. Check the condition and connections of the ionization circuit (cable(s) and measurement bridges). Adjust, clean, or replace the electrode(s). Connect or replace the cable(s). Replace the transformer, control unit, or compact gas unit. Also, check the cabling between the ...

Summary

Function: Gas train VR4625; MB-DLE 407

Function: Automatic control unit TCG 1 xx with TC function

Function: Automatic combustion control unit TCG 1 xx without TC function

Operation and control

Details the operation of the TCG 1xx automatic gas combustion control unit without TC function.

Function: Operating and Safety Functions

Operating function

Describes the operational sequence and behaviour of the burner during various states.

Safety function

Details the safety mechanisms and responses to prevent hazardous situations.

Function: Specific Operating and Safety Functions (Burners without TC)

Details for burners without TC

Focuses on operating and safety functions for burners without TC function.

Assembly: Burner assembly and gas connection

Start up: Checks and Ionisation Measurement

Start up: Adjustment Data and Air Regulation

Start up: Setting the VR4625 Compact Gas Unit

Start up: Setting the MB-DLE407 Compact Gas Unit

Start up: Air Pressure Switch and Operating Checks

Service and Maintenance

Troubleshooting

Fault Diagnosis and Repair

Provides a fault diagnosis table with causes, remedies, and safety component replacement guidelines.