04/2011 - Art. Nr. 4200 1037 0000A
VG 2.140
VG 2.200
de, fr, it................................. 4200 1036 9900
nl
en
............................................. 4200 1036 9800
Originele bedieningshandleiding
Voor de gespecialiseerde vakman
Aangeblazen gasbrander...................... 2-18
Original operating instructions
For specialist installation engineers
Gas burners ......................................... 19-35

Questions and Answers

  • J
    Jessica BurnsAug 9, 2025
    Why elco VG 2.140 Burner does not start with normal gas pressure?
    • F
      farmerkaylaAug 9, 2025
      If the Elco Burner does not start, but you have normal gas pressure, it might be due to insufficient gas pressure or a gas pressostat that is wrongly set or defective. To resolve this, check the gas lines, clean the filter, and inspect or replace the gas pressostat or the compact gas unit.
  • W
    William JohnsonAug 15, 2025
    What to do if the elco VG 2.140 Burner switches off during operation?
    • A
      Amber SampsonAug 16, 2025
      If the Elco Burner switches off during operation, it could be due to the air pressure switch contact opening during start-up or operation, or a flame failure during operation. You should adjust or replace the pressure switch and check the ionization sensor circuit. Also, check or replace the automatic combustion control unit.
  • M
    Mary JonesAug 21, 2025
    Why Elco Burner does not start after thermostat shutdown?
    • S
      samantha05Aug 21, 2025
      If the Elco Burner does not start after thermostat shutdown and there's no malfunction indicated on the automatic combustion control unit, it could be due to a drop in supply voltage, a power failure, or a control unit malfunction. Check the cause of the voltage drop or power failure and replace the control unit.
  • M
    mpageAug 27, 2025
    How to solve no heat request in Elco Burner?
    • S
      Sally ArcherAug 27, 2025
      If there is no heat request for the Elco Burner, it is possible that the thermostats are defective or incorrectly adjusted. To solve this, adjust the thermostats or replace them if necessary.
  • S
    Shaun DouglasNov 3, 2025
    What to do if the Elco Burner starts, the ignition switches on, then failure?
    • T
      Tracy NicholsNov 3, 2025
      If the Elco Burner starts, the ignition switches on, but then there's a failure, it could be due to several reasons, including no flame at the end of the safety period, incorrect gas throughput, a faulty flame monitoring circuit, no ignition arc, short-circuited electrode(s), damaged ignition cable, a defective ignition transformer or automatic combustion control unit, solenoid valves that don't open, or valves jamming. To address this, adjust the gas throughput. Inspect the condition and position of the ionization sensor. Check the condition and connections of the ionization circuit (cable(s) and measurement bridges). Adjust, clean, or replace the electrode(s). Connect or replace the cable(s). Replace the transformer, control unit, or compact gas unit. Also, check the cabling between the ...

Summary

Important Information

Burner Description

Function

Operating Function

Describes the burner's start-up sequence and operational phases.

Safety Functions

Details the safety mechanisms and shutdown procedures.

Automatic Combustion Control Unit TCG 1 xx

Explains the operation and features of the TCG 1xx control unit.

Allocation Chart Connection Socket

Provides a detailed mapping of terminal connections for the burner.

MB-DLE Gas Train

Details the MB-DLE compact gas train and its technical specifications.

Assembly

Burner Assembly

Instructions for physically assembling the burner components.

Burner Tube Installation Depth and Brickwork Surround

Guidance on burner tube placement and surrounding insulation.

Exhaust Gas Evacuation System

Recommendations for flue gas system connections to minimize noise.

Inspection Glass Cooling

Describes fitting a connection for cooling the boiler inspection glass.

Gas Train Checking;Setting the Mixing Unit

Procedures for checking and setting the gas train and mixing unit.

Electrical Connection

Instructions for making the electrical connections to the burner.

Checks Before Commissioning

Essential checks to perform before initial burner operation.

Ionisation Current Measurement

Method for measuring ionisation current for flame monitoring.

Commissioning

Adjustment Data

Tables and notes for setting burner parameters like gas pressure.

Air Regulation

How to adjust combustion air flow for optimal performance.

Setting the MB-DLE Compact Gas Unit

Detailed steps for setting the MB-DLE compact gas unit.

Setting the Gas Pressostat

Procedure for setting the gas pressure shut-off switch.

Air Pressure Switch Adjustment

Instructions for adjusting the air pressure switch.

Operating Check

How to perform functional checks of the burner system.

Servicing

Maintenance

Recommendations for annual burner maintenance by qualified personnel.

Checking the Mixing Unit

Steps for inspecting and checking the burner's mixing unit.

Cleaning the Fan Wheel

Procedure for removing and cleaning the fan wheel.

Fitting the Fan Wheel

Guidance on correctly fitting the fan wheel during replacement.

Replacing the Flame Tube

Instructions for removing and fitting the burner's flame tube.

Filter Replacement

Steps for checking and replacing the multiblock filter element.

Cleaning the Air Intake Box

How to remove, clean, and reassemble the air intake box.

Cleaning the Cover

Recommended methods for cleaning the burner cover.

Troubleshooting

A guide to diagnosing and repairing common burner faults.

Maintenance Frequency Indicator

How to interpret and manage the maintenance indicator on the control unit.

elco VG 2.140 Specifications