02/2009 - Art. Nr. 4200 1015 7800A
VECTRON ECO 1.34
VECTRON ECO 1.35
VECTRON ECO 1.50
VECTRON ECO 1.52
VECTRON ECO 1.75
Bedieningshandleiding
Voor de gespecialiseerde vakman
Aangeblazen oliebrander Low NOx ..... 2-13
nl
Operating instructions
For authorised specialist
Low NOx
forced-draught fuel-oil burner
14-25
en
de, fr, it................................. 4200 1015 7700
............................................. 4200 1015 7900

Questions and Answers

  • J
    Jessica JonesAug 2, 2025
    What to do if my elco Burner does not start but shows no malfunction?
    • I
      ifreemanAug 2, 2025
      If your elco Burner doesn't start and the automatic combustion control unit shows no malfunction, it could be due to a drop in supply voltage or a power failure. You should check the cause of the voltage drop or power failure. Another possible cause is a control unit malfunction, in which case you should replace the control unit.
  • R
    ramossusanAug 12, 2025
    Why does elco Burner start and then shut down after preventilation?
    • B
      Brianna TorresAug 12, 2025
      If the elco Burner starts and then shuts down after preventilation, it could be due to a parasitic flame during the preventilation/pre-ignition phase. You should check the ignition sparks and adjust or replace the electrode. Also, check or replace the fuel-oil solenoid valve.
  • S
    Shannon HamiltonAug 21, 2025
    How to fix elco Burner with no heat request?
    • S
      Steve JonesAug 22, 2025
      If there is no heat request for your elco Burner, the thermostats might be defective or incorrectly adjusted. Adjust the thermostats or replace them if necessary.

Summary

Important Notes

Burner Description

Components and Diagram

Detailed breakdown of the burner's physical components and their layout.

Function

Heating Function

Describes the burner's operation when heat is requested by the system.

Operating Function

Outlines the burner's sequence during normal operation after ignition.

Safety Function

Explains the safety shutdown procedures and conditions for the burner.

Principle Diagram

Illustrates the basic functional components and their interconnections.

Automatic Combustion Control Unit TCH 1 xx

Details the control unit, its functions, and operating sequence.

Allocation Chart Connection Socket

Provides a detailed chart of terminal and connector assignments for electrical connections.

Assembly

Burner Assembly and Installed Depth

Covers the physical mounting of the burner and setting the installed depth.

Flame Tube Installation

Instructions for installing the flame tube into the burner head.

Electrical and Oil Connections

Guides on making the necessary electrical and fuel oil line connections.

Checks Before Commissioning

Lists essential checks to perform before the initial start-up of the burner.

Start Up

Adjustment Data and Air Regulation

Provides tables and instructions for setting burner output and air intake.

Oil Pressure Regulation

Explains how to adjust and check the fuel oil pressure for optimal output.

Operating Check

Details critical checks to ensure proper burner operation and safety functions.

Service

Maintenance Overview and Positions

Outlines general maintenance procedures and specific work positions.

Checking Exhaust Gas Temperature

Describes how to monitor flue gas temperature for boiler efficiency.

Blower Wheel Assembly

Instructions for correctly assembling or replacing the blower wheel.

Maintenance Frequency and Fuel Oil Indicators

Explains how to interpret and use the unit's maintenance and fuel level indicators.

Troubleshooting

Fault Diagnosis and Repair

Provides a systematic approach to identifying and resolving burner malfunctions.

elco VECTRON ECO 1.34 Specifications

General IconGeneral
Brandelco
ModelVECTRON ECO 1.34
CategoryBurner
LanguageEnglish