9-12
HOW TO USE YOUR MOTORHOME’S EQUIPMENT
Troubleshooting
Before contacting your dealer or authorised service centre, please check whether:
The instructions for correct operation of the refrigerator have been observed.
The refrigerator is standing level.
It is possible to operate the refrigerator with any available power source.
Failure: The refrigerator does not cool sufficiently
Possible cause Action you can take
•Inadequate ventilation to the unit. Check that the ventilation grilles are not
covered.
Thermostat setting is too low. Set thermostat to a higher level.
The condenser is heavily frosted. Check that the refrigerator door closes
properly.
• Too much warm food has been stored Allow warm food to cool down before storage.
within short period of time.
The appliance has been running for only Check whether the cooling compartment works
a short period of time. after approx. 4-5 hours.
Ambient temperatures too high. Regularly remove ventilation grilles.
Failure: The refrigerator does not cool in gas operation mode
Possible cause Action you can take
Gas cylinder empty. Change gas cylinder.
•Is the upstream shut-off device open? Open shut-off device.
•Air in the gas pipe? Switch off the appliance and start again.
Repeat this procedure 3-4 times, if necessary.
Failure: The refrigerator does not cool in 12V operation
Possible cause Action you can take
On-board fuse defective. Fit new fuse.
On-board battery discharged. Check battery, charge it.
Engine not running. Start engine.
Heating element defective (please also Please inform the Dometic Customer
refer to failure indication). Services.