Troubleshooting
Do not repair or disassemble the unit by yourself, unauthorized repair attempts will invalidate the
warranty and may cause bodily harm.
Trouble
Reas
on
Solution
The unit does not
work
No power supply Power-on and turn on the unit.
Water
-
full indicator illuminate
Drain the
internal
water
tank
Timer function is active
Cancel Timer function
Room temperature too low or too
high
Use only
in
ambie
nt temperature
s
between
7-40
The unit does not
seem to perform.
In direct sunlight Draw the curtains, UV affects RC
Windows or doors open.
Large amount of people or a heat
source in the room.
Close windows and turn on another air
conditioner
Filter
is very dirty
Clean or change the air filter
Air inlet or air outlet is blocked
Clear out
debris
Room temperature is lower than
setting temperature
Change the setting temperature
The unit loud The unit is not put on flat surface Put the unit on flat and hard surface
Compressor does
not work
Overheating protection is active
Check venting.
Restart the unit after 5 minutes when
compressor has cooled
Remote control
doesn’t work
Operating distance is too far.
Move remote control closer to the unit and make
sure it aims at the air-outlet grille
Control panel has
t received the
signal from remote control.
The batteries
are flat
Replace
the batteries
E1 on LCD
Coil temperature is abnormal
Refer to Service Centre
(check coil temperature sensor or relevant
circuit)
E2 on LCD
Room temperature is abnormal
Temperature not within 5
-
40 C operating range. If
temperature within operating range refer to
Service Centre (check room temperature sensor
or relevant circuit)
E3 on LCD
No refrigerant or there is very little
refrigerant
Refer to Service Centre (c
heck leakage,
wielding
,
vacuum pump, charge refrigerant according to
name plate)
E4 on LCD
Anti-freezing protection
W
aiting for defrosting.
Function will recover automatically. No user input
needed.
FL
on LCD
Water tank is full inside the machine
Drain out water from drain port at bottom rear of
the unit.
F1 on LCD High pressure protection
After inside gas pressure comes down, it will
function normally. No user input needed
If the above solutions do not resolve the problem please contact the service centre.