Installation manual
35
8.2 Electrical connections
ELD-618
Electrical connections
Heating alternative Main voltage Hz Heating power
kW
Total power
kW
Recommended
fuse
ITCB A
Electric heated 208-240V 1~ 60 3.0/5.4/7.5 3.4/5.7/7.8 20/30/40
208-240V 3~ 60 3.0/5.4/7.5 3.4/5.7/7.8 15/20/25
440V 3~ 60 5.4/7.5 5.7/7.9 15/15
480V 3~ 60 5.4/7.5 5.7/7.9 15/15
Non heated/Steam heated 120/440/480V 1/3~ 60
1
0.5 15
208-240V 1~ 60
1
0.4 15
1. Total power and recommended fuse does not depend on the heating power in those cases.
ELD-620
Electrical connections
Heating alternative Main voltage Hz Heating power
kW
Total power
kW
Recommended
fuse
ITCB A
Electric heated 208-240V 1~ 60 3.0/5.4/7.5 3.4/5.7/7.8 20/30/40
208-240V 3~ 60 3.0/5.4/7.5 3.4/5.7/7.8 15/20/25
440V 3~ 60 5.4/7.5 5.7/7.9 15/15
480V 3~ 60 5.4/7.5 5.7/7.9 15/15
Non heated/Steam heated 120/440/480V 1/3~ 60
1
0.5 15
208-240V 1~ 60
1
0.4 15
1. Total power and recommended fuse does not depend on the heating power in those cases.
ELD-625
Electrical connections
Heating alternative Main voltage Hz Heating power
kW
Total power
kW
Recommended
fuse
ITCB A
Electric heated 208-240V 1~ 60 3.0/7.5/10.0 3.5/7.9/10.4 20/50/60
208-240V 3~ 60 3.0/7.5/10.0 3.5/7.9/10.4 15/30/35
4403V 3~ 60 7.5/10.0 7.9/10.4 15/20
480V 3~ 60 10.0 10.4 20
Non heated/Steam heated 120/440/480V 1/3~ 60
1
0.6 15
208-240V 1~ 60
1
0.5 15
1. Total power and recommended fuse does not depend on the heating power in those cases.
ELD-630
Electrical connections
Heating alternative Main voltage Hz Heating power
kW
Total power
kW
Recommended
fuse
ITCB A
Electric heated 208-240V 1~ 60 3.0/7.5/10.0 3.5/7.9/10.4 20/50/60
208-240V 3~ 60 3.0/7.5/10.0 3.5/7.9/10.4 15/30/35
4403V 3~ 60 7.5/10.0 7.9/10.4 15/20
480V 3~ 60 10.0 10.4 20
Non heated/Steam heated 120/440/480V 1/3~ 60
1
0.6 15
208-240V 1~ 60
1
0.5 15
1. Total power and recommended fuse does not depend on the heating power in those cases.