EasyManua.ls Logo

Electrolux Professional Compass Pro ELD-618 - Steam Connection

Electrolux Professional Compass Pro ELD-618
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation manual
45
9 Steam connection
Inlet pipes connected to the machine must be equipped with a manual shut-off valve to facilitate installation and serv-
icing. The connection hose must be of type ISO/1307- 1983 or equivalent.
Connection size at filter: DN 15 (BSP 1/2").
Demount the top panel (A). Demount the casing (B).
A
B
fig.6600
Mount the nipple to the steam valve. Mount the steam valve on the machine. Mount nipple, strainer and elbow. Note
the direction of the strainer. Mount steam hose to the elbow. Check that there are no sharp angles or bends on the
connected steam hose.
fig.5862C
Mount the hose with wires between steam valve and machine. Connect the wires to the steam valve. Connect ground
cable to the terminal ground connection. Connect the ”HEAT” cable connector to the ”HEAT” terminal on the I/O
board.
HEAT
fig.6604B
Steam pressure required:
minimum: 50 kPa / 7 psi
maximum: 800 kPa / 115 psi
recommended: 600 kPa / 87 psi
Note!
A steam heated machine is only intended to use clean steam.

Related product manuals