2010 dmm 52/96 599 73 68-54
11.5 Heating element
• When replacing the heating element, please refer to the code shown in the list of
spare parts relating to the appliance.
• It is strictly forbidden to tamper with the heating element in
any way!!!
(e.g. changing the NTC probe, etc...)
11.5.1 General characteristics
1. NTC probe
2. Heating element
The heating element of the washing water is armoured, i.e. it is inserted in sealed tubular stainless steel casing.
It is powered by two relays (K1, K2) situated in the circuit board. It is fitted with two thermal fuses which trip if
the temperature of the heating element exceeds the values for which they were calibrated.
(In the event of a fault, an alarm is displayed - see table of alarms).
1. Main circuit board
11. Heating element
1
2