Error Codes
E57
More than 20 amps sensed on inverter
Refer to test (9).
E58
More than 8.5 amps sensed on motor phase
Refer to test (9).
E59
No signal from tachometer for 3 seconds
Refer to test (10).
E5C
Main control received high voltage
Replace the motor control board.
E5D
Communication problem
Refer to test (11).
E5F
Main control board continuously resets
Refer to test (11).
E67
Heater relay sensing failure
Refer to test (15).
E68
Ground current leakage on heater or fuse is
open.
Refer to test (14).
E71
NTC (tub heater) failure
Check wiring. If wiring checks good, replace
main control board
E91
Communication error between main board
and user interface
Check wiring.