6.16. Service function / manufacturing test routine:
General information Calling above-mentioned function
w Calling the service functions is executed in all designs
Calling the function "manufacturing test routine"
resp. key arrangements analogously.
w For that you always have to use keys S0
, S1, S2 and S3
1.
Appliance in switched-off condition
independent of their variant-depending program load.
w In the service function mode the key S3
is ALWAYS
2.
Press keys S1 and S3 simultaneously and ...
responsible for calling the "manufacturing test routine".
3. / 4.
... and switch on the appliance by ON/OFF switch S0.
For that keep the keys S1
and S3 pressed until the 3
acceptance LEDs LD1
, LD2 and LD3 are flashing.
(A temporary flashing up of LEDs is possible and is no fault! )
5.
By actuating the function key S3 you can call the
manufacturing test routine.
The key LED LD3
continues flashing, the LEDs LD1
and LD2 go out.
6.
The test routine starts automatically.
The key LED LD3
continues flashing.
From that moment the same input philosophy is valid for the
manufacturing test routine as for normal washing cycles
F cycle run and cycle end
(see description page B 5)
F clear cycle in advance
(see description page B 6)
F interrupt program
(see description page B 8)
Generally it is valid:
For calling all service functions you always have to
actuate function keys S1
and S3 before switching
on the appliance by ON/OFF switch S0
!
The keys have to remain pressed aprox. 4 seconds to
activate the function.
This procedure is intentionally different to that for the
customer functions.
EDW 1003 / VGA
LD1 LD2 LD3
S1 S3
ENDE
S0
2.
1.
3.
S0
3-4 Sekunden
5.
4.
S1 S3 S0
LD1 LD2 LD3
alle blinken
LD1 LD2 LD3 LD4 LD5 LD6
S1 S2 S3 S4 S5 S6
LD7
LD8
LD9
LD10
LD11
LD12
S0
S0S1 S3
S1 S3
S0
LD3
S3
blinkt
6.
S0
LD3
Fertigungsprüfprogramm läuft