EasyManua.ls Logo

Electrolux EW30ES6CGS6 User Manual

Electrolux EW30ES6CGS6
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
United States
iNSTALLATiON AND SERVICEMUST BEPERFORMED BY A QUALiFiED iNSTALLER.
iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
Canada
For existing 29" (73,7 cm) cutout wide opening, you must call the Service Center for
optional thinner side trims. Also you must prepare the countertop edge as shown in
the "Countertop Preparation" section (see page 8).
These surfaces should be flat &
leveled (hatched area).
/2"min,
30" Min.
(76,2 cm) Min. ,
30" Min. (see Note 3) T
(76,2 cm) Min. (See Note 3) |
18" Min.
/8"min. (45,7 cm) Min.
Shave Raised
Edge To Clear
Space for
31 1/2"
(80 cm)
Wide
Cooktop Rim.
1 1/2"Max.
(3,8 cm Max.)
Locate Cabinet Doors 1" (2,5 cm)
Min. From Cutout Opening
Grounded Junction Box or Wall Outlet Should Be
Located 8" to 17" (20,3 - 43,2 cm) From Right
Cabinet and 2" to 4" (5,1-10,2 cm) From Floor
_rox. 1 7/8"
(4,8 cm)
24" Min.
(61 cm) Min
Do not install the unit in the cabinet before reading next two pages.
A: HEIGHT B: WIDTH C. CooKToP B: TOTAL DEPTH TO
(Under Cooktop) WIDTH FRONT OF RANGE
E. CUTOUT WIDTH***
(Countertop
and cabinet)
353/4"(90,8cm) 30"(76,2cm) 31 1/2" 285/16"(71,9cm) 30_+1/16"
(80 cm) (76,2_+0,15 cm)
36 5/8" (93 cm)
F: cUTouT' G: HEIGHT
DEPTH OF COUNTERTOP
|
21 3/4" (55,2 cm) Min.
22 1/8" (56,2 cm) Max
24" (61 cm) Min. with
backguard
35 3/4" (90,8 cm) Min.
36 5/8" (93 cm) Max.
Printed in United States
P/N318201615 (1003) Rev.G
English - pages 1-12
Espahol - p_iginas 13-24
Fran_ais - pages 25-36
Question and Answer IconNeed help?

Do you have a question about the Electrolux EW30ES6CGS6 and is the answer not in the manual?

Electrolux EW30ES6CGS6 Specifications

General IconGeneral
BrandElectrolux
ModelEW30ES6CGS6
CategoryRanges
LanguageEnglish

Summary

Cabinet and Countertop Preparation

Flat and Leveled Surfaces

Ensure countertop surfaces are flat and leveled for proper range installation.

Electrical Outlet Location

Locate the grounded junction box or wall outlet for proper connection.

Cutout Width and Centering

Preventing Cooktop Breakage

Ensure the appliance is centered in the counter opening to avoid cooktop breakage.

Matching Widths

Cabinet and countertop width must match the cutout width for proper fit.

Handling and Installation Precautions

Avoid Cooktop Manipulation

Do not handle or manipulate the unit by the cooktop to prevent breakage.

Leveling Leg Adjustment

Adjust leveling legs and wheels for proper height and support.

Important Safety Instructions

General Safety Warnings

Covers child safety, fire risks, and proper usage of the range.

Installer and Consumer Notes

Important notes for installers and consumers regarding electrical safety and reference.

Serial Plate Location

Locate and record the serial number for future reference.

Electrical Connection (U.S.A.)

Power Supply Cord Kit

Instructions for connecting the power supply cord kit in the USA.

Terminal Block Access

Accessing the terminal block and grounding strap for electrical connection.

Electrical Shock Hazard Warning

Warning regarding electrical shock hazard during installation.

Range Wiring

Three Conductor Wire Connection

Connects the three-conductor power supply cord to the range terminal block.

Four Conductor Wire Connection

Connects the four-conductor power supply cord to the range terminal block.

Direct Electrical Connection

3-Wire System Connection

Connecting to a 3-wire system, allowing grounding conductor to neutral wire.

4-Wire System Connection

Connecting to a 4-wire system, not allowing grounding conductor to neutral wire.

Cabinet Construction and Countertop Prep

Cabinet Storage Above Range

Warning against cabinet storage above range to prevent burn/fire risk.

Countertop Preparation

Prepares countertops for range fit, including shaves and trims.

Existing 29" Cutout Width

Specific preparation for existing 29" cutout width for optimal fit.

Range Installation Steps

Standard Installation Procedure

Step-by-step guide for standard range installation into the cabinet.

Accessory Installation Notes

Information on installing optional accessories like side trims or backguards.

Leveling and Operation Check

Leveling the Range

Adjust leveling legs and wheels to ensure the range is level.

Checking Range Operation

Verify operation of surface elements, oven, and other functions.

Anti-Tip Bracket Installation

Anti-Tip Bracket Installation

Instructions for installing anti-tip brackets to prevent range tipping.