18:2
Flow meter calibration
o If amount of water is not correct adjust the K-factor until the correct amount
is achieved.
o Be sure no other machine connected to the same water line is filling water at
the same time the calibration is done.
• ProcedureB:
If a high quality and resolution calibrated laboratory flow meter is connected in se-
ries with the reference machine flow meter, the following procedure may be imple-
mented instead:
o SelecttheCotton60°Cprogram(oranyotherIECcottonprogram).
o Start the program without load.
o Pause the program after first fill.
o Read the laboratory flow meter and compare with the 26 litres the reference
flow meter is to supply.
o If the amount of water is incorrect, adjust the K-factor until the correct
amount is achieved.
o Rapid advance the program to its end.
o Be sure no other machine connected to the same water line is filling water at
the same time the calib