AOS OVENS - Service Manual
(595889300 – ENG)
Name Description
hboL Boiler hour counter
HbYP Max humidity value to stop the boiler
HCCP HACCP Mode
hcMb Combi hour counter
hStM Steam hour counter
HUIM Pulse length of manual humidifier
HUon ON phase of the humidifier with combi cycle beetween 50 and 100 degrees
I Parameter i of SCELON=SCEL(1+p/400)-i (FUZZY-LOGIC)
ISG Define if the oven is an ISG oven (0 means oven with boiler)
LAMb Presence of lambda probe (1=yes)
LAnG Language for the menu
MHUM Flag manual humidifier 0=Off 1=On
MISG Max temperature allowed for water injection in ISG
nMod Define if the modification of store program is disable
nPrG Max number of programs
OCA1 OFFSET of first cavity probe
OCA2 OFFSET of second cavity probe
OLbd Calibration of the lambda probe
OPr1 OFFSET of first probe of 6-point meat probe
OPr2 OFFSET of second probe of 6-point meat probe
OPr3 OFFSET of third probe of 6-point meat probe
OPr4 OFFSET of fourth probe of 6-point meat probe
OPr5 OFFSET of fifth probe of 6-point meat probe
OPr6 OFFSET of sixth probe of 6-point meat probe
pdEr Sample period to calculate the derivative value (FUZZY-LOGIC)
PI Parameter p of SCELON=SCEL(1+p/400)-i (FUZZY-LOGIC)
PPM Flag to enable Peak Power Management (0=disable; 1=enable)
Sbc Cooling temperature set for board ventilation
SbYP Bypass temperature with max. cooking cavity steam temperature (calibration)
SEAL Altitude above sea level
SInC Boiler temperature that detect presence of scale
SPHb Preheating temperature of the boiler
SPHF Boiler temperature during leavening
Stbo PWM value at start of boiler burners
StbP Steam condenser engagement in "boiler" mode
StcA PWM value at start of cavity burners
StoF Minimum time for "switch off" of boiler
Ston Minimum time for "switch on" of boiler
tbon Timeout for E SL alarm, water level probe alarm
tcdb Max water temperature for boiler drain
thMA Define the max. temperature limit for the manual injection of water
tPrm Print frequency (0=no print)
trMA Define the max. temperature for water injection during cooling phase
trMn Define the min. temperature for water injection during cooling phase
File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.31/40