EasyManua.ls Logo

Electrolux TT500 - Technical Data - Type 300;30

Electrolux TT500
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation - electric, steam and gas heating
487 18 39 01 - 300/500/750 - GB
28
Technical data, type 300/30
Heating Electric Steam Gas
Drum volume: 286 litres 286 litres 286 litres
Weight: Net 220 kg 220 kg 220 kg
485 lb 485 lb 485 lb
Drum: Diameter 680 mm 680 mm 680 mm
Depth 790 mm 790 mm 790 mm
Revolutions per minute 44 rpm 44 rpm 44 rpm
G-factor 0.8 0.8 0.8
Capacity: 13.6 kg 13.6 kg 13.6 kg
30 lb 30 lb 30 lb
Motor: Effect without reverse 0.37 kW 0.37 kW
Effect with reverse 2 x 0.37 kW 2 x 0.37 kW
Revolutions per minute 50 Hz 1400 rpm 1400 rpm
Revolutions per minute 60 Hz 1680 rpm 1680 rpm
Effect of drum motor 0.37 kW
Effect of fan motor 0.37 kW
Drum motor- revolutions 50 Hz 1400 rpm
Drum motor- revolutions 60 Hz 1680 rpm
Fan motor - revolutions 50 Hz 1400 rpm
Fan motor - revolutions 60 Hz 1680 rpm
Heat effect: Electric heating 13.5 kW
Electric heating 18.0 kW
Gas heating 21.0 kW
Air consumption:Electric 13.5 kW 430 m
3
/h
Electric 18.0 kW 690 m
3
/h
Steam 925 m
3
/h
Gas 690 m
3
/h
Pipe connection: Evacuation Ø 200 Ø 200 Ø 200
Steam: ISO 7/1-Rp1/2
Condensate outlet: ISO 7/1-Rp1/2
Steam: Recommended pressure (absolute) 100-1000 kPa
Max. allowable pressure 1000 kPa
Drop in pressure:Evacuation
Gas pipe connection: ISO 7/1-R1/2
Gas pressure: See page regarding pressure
Noise level: < 70 dB (A) < 70 dB (A) < 70 dB (A)
Variable, depen-
dent upon
steam pressure
max.
80 Pa
max.
20 Pa
max.
80 Pa

Table of Contents

Related product manuals