Installation - electric, steam and gas heating
487 18 39 01 - 300/500/750 - GB
30
Technical data, type 750/75/650
Heating Electric Steam Gas
Drum volume: 650 litres 650 litres 650 litres
Weight: Net 350 kg 355 kg 345 kg
772 lb 783 lb 760 lb
Drum: Diameter 913 mm 913 mm 913 mm
Depth 998 mm 998 mm 998 mm
Revolutions per minute 44 rpm 44 rpm 44 rpm
G-factor 0.9 0.9 0.9
Capacity: 34.1 kg 34.1 kg 34.1 kg
75 lb 75 lb 75 lb
Motor: Effect of drum motor 0.37 kW 0.37 kW 0.37 kW
Effect of fan motor 0.75 kW 0.75 kW 0.75 kW
Drum motor- revolutions 50 Hz 1400 rpm 1400 rpm 1400 rpm
Drum motor- revolutions 60 Hz 1680 rpm 1680 rpm 1680 rpm
Fan motor - revolutions 50 Hz 2800 rpm 2800 rpm 2800 rpm
Fan motor - revolutions 60 Hz 3300 rpm 3300 rpm 3300 rpm
Heat effect: Electric heating 30.0 kW
Electric heating 36.0 kW
Gas heating 57.0 kW
Air consumption:Electric 30.0 kW 1500 m
3
/h
Electric 36.0 kW 1500 m
3
/h
Steam 1500 m
3
/h
Gas 1500 m
3
/h
Pipe connection: Evacuation Ø 200 Ø 200 Ø 200
Steam: ISO 7/1-Rp 3/4
Condensate outlet: ISO 7/1-Rp 3/4
Steam: Recommended pressure
(absolute) 100-1000 kPa
Max. allowable pressure 1000 kPa
Drop in pressure:Evacuation
Gas pipe connection: ISO 7/1-R3/4
Gas pressure:
Noise level: < 70 dB (A) < 70 dB (A) < 70 dB (A)
Variable, depen-
dent upon
steam pressure
max.
340 Pa
max.
340 Pa
max.
340 Pa
See page regarding pressure