Parameter programming
48
487 18 39 01 - 300/500/750 - GB
Temperature setting
Reversing
Time setting
Parameter no.
check by pressing
the clock button
Value
can be set after two seconds
Required change:
Press the “count up/down” buttons.
The highest temperature
can be set to a value
between 32°C-85°C.
Factory setting = 85
Temperature
program High
Count down Count up
The medium temperature
can be set to a value
between 32°C-85°C.
Factory setting = 70
Temperature
program
Medium
Temperature
hysteresis
Difference
between
heat
on or off
Time interval
Running time
per pulse
(per coin insert -
or push
if time-
controlled)
Running time
between reversals
Max. running
time or
Time inter-
val,
coin 2
Max. running
time on manual
machine or
running time per
coin insert on
coin 2 (double
insert)
Temperature-
program Low
Can be set to a value
between 01°C-10°C.
Factory setting = 02
Can be set to a value
between 0.1 and 90 minutes.
Factory setting = 15
Lowest temperature
can be set to a value
between 32°C-85°C.
Factory setting = 50
From 0.1 to 9.9 minutes the setting can
be changed by increments of
1/10 minute per push.
From 10 to 90 minutes the setting can
be changed by increments of
1 minute per push.
Can be set to a value
between 0.1 and 90 minutes.
Factory setting = 60
Can be set to a value
between 0.1 and 9,9 minutes.
Factory setting = 5.0
From 0.1 to 9.9 minutes the setting can
be changed by increments of
1/10 minute per push.
From 10 to 90 minutes the setting can
be changed by increments of
1 minute per push.
Change the setting by
1/10 minute per push.
Next para-
meter