Tango 0060 5-2021
Installation
Use the provided shims on
the rear legs if necessary
to level the Tango. Angled
slightly forward is also OK
Power:
NEMA L6-30
30 Amps
Minimum 200 Volts
Maximum 242 Volts
The transformer MUST be ad-
justed to match the incoming
voltage! (See next page)
Water: Minimum Maximum
Pressure 45 PSI 100 PSI
Flow Rate 1 Gallon/ Minute
TDS 50 ppm 125 ppm
Total Hardness 3 GPG 5 GPG
PH 6.5 7.5
Free Chlorine na 0.5 ppm
Total Chlorine na 1 ppm
Drain:
Tango must be installed level
or angled slightly forward!
Install the drain line running
continuously downward so
that no “trap” is formed.
!
Back pressure in the drain
line will cause problems
with the brewing system.
!