- Door safety interlock
- Drain pump
- Motor up to 650 rpm then at
maximum spin speed (**)
Door closed.
Water level lower
than anti-boiling level
for spinning.
Drain, calibration
of analogue
pressure switch
and spin.
Drum speed in
rpm/10
11
- Reading/Deleting the last alarm ----- ----
12
÷
16
- The LEDs, groups of symbols
in the LCD screen and the
backlight of the display are
turned on in sequence
- Press a button/sensor to turn
on the group of icons in the
LCD screen or the
corresponding LED and the
buzzer sounds at the same
time
Always active.
User interface
functions.
(*) In most cases, this time is sufficient to check the heating. However, the time can be increased by repeating the phase without draining
the water: pass for a moment to a different phase of the diagnostic cycle and then back to the heating control phase (if the temperature is
higher than 80 °C, heating does not take place).
(**) The check at the maximum speed occurs without control of the A.G.S. and no garments must be inside the appliance.