Info Information on the heating system status
Auto Setting AUTO mode, thermostat will be work acc. last setting weekly program
Manu Setting MANU mode, thermostat will be keep last setting temperature
Off Heating system switched off permanently. ; to cancel the function, use the
Temp xx message, thermostat will automatically enter into the MANU mode with the
given temperature or SMS message Auto (for AUTO mode) or Manu (for MANU)
Temp xx Required temperature change (only integer numbers can be entered, they must fall
within the permitted range of maximum and minimum temperatures –CONST2 and
CONST3).
Call Back call
xx = temperature value in °C (always a two-digit number, e.g. 05)
!
Requir: xx.x Temperature required (user set)
Act: xx.x Current room temperature
Set on
Set off
Heating system On
Heating system Off
AUTO
MANU
OFF
Thermostat in automatic AUTO mode
Thermostat in manual MANU mode
Thermostat in the OFF mode (permanently off)
Sig: x Signal strength at the place where the module is located; where x is the
value within the range of 0 to 5:
0..undeterminable or no signal detected
1..the worst strength
5..the best signal strength
Sens 2: xx.x Current temperature of the external sensor
Battery! Low batteries in the thermostat
Noakcept! Error indicated (wrong SMS format, etc.)
xx.x = temperature value in °C
SIGNAL GSM x Determines the signal strength at the place where the thermostat is located;
where x is a value within the range from 0 to 5:
0..undeterminable or no signal detected
1..worst level
5..best level of signal
REQUIR TEMP Information on the desired temperature preset
PROGR 3 PERIOd 2 Information on the program preset (e.g., 3) and the time interval running
(interval 2)
SMS RECEIVEd Information the thermostat received new SMS
HOLIdAY IN 22.7 Only displayed in the holiday mode; informs on the end of holiday when the
thermostat restores the last selected AUTO/MANU mode.
T EXT SENS 25.0 Current temperature of the external sensor, displayed only if the sensor is
connected
EXT SENS STOP If the preset limit temperature of the external sensor in the maximum fl oor
temperature monitoring function is exceeded (see page 7), the thermostat is
switched off
9
Info: If using a credit card, you must make a paid call once in 3 months. This call is executed automatically (in 80 days, between 4 and 9
PM) to the phone number entered in the thermostat (CONST tEL nO); after 20 s, the call is terminated automatically. You can execute this
function earlier by means of the “Call” SMS message.
Note: If the minimum / maximum room temperature (preset CONST 2 and 3) is exceeded, the “WARNING” SMS is
automatically sent in a form similar to that in the „Info“ form (only if you enter phone number to the thermostat, see CONST tEL nO).
BACK MESSAGES ARE SENT WITHIN 3 MINUTES!
FORMS OF BACK MESSAGES FROM THE THERMOSTAT
Any type of mobile phone can be used for sending and receiving back messages!
If you can set the font size (format) in your phone, always use the MEDIUM size when writing messages
(if there are three options), or the BIG size (if there are two options).
FORMS OF MESSAGES SENT
INFORMATION IN THE LCD DYNAMIC LINE