Hybrid Controller
“Diesel – PV Off the shelve”
Manual
Version 2.5
elgris GmbH
Langerweher Str. 10
D-52459 Inden
Germany
www.elgrispower.com
info@elgrispower.com
Question and Answer IconNeed help?

Do you have a question about the elgris HYBRID BASIC and is the answer not in the manual?

elgris HYBRID BASIC Specifications

General IconGeneral
Supply voltage24 V DC
Power consumption5 W
Number of digital inputs8
Number of digital outputs8
Number of analog inputs2
Number of PWM outputs2
Protection classIP20
Weight150 g
Communication interfacesRS485
Operating temperature-20°C to +60°C

Summary

Introduction to Hybrid Controller

Version Overview

States that the HYBRID BASIC series controller currently consists of one model.

Installation Procedures

Safety Instructions

Outlines essential safety measures to follow before and during installation.

Device Overview

Describes the physical components and layout of the HYBRID BASIC controller.

Pin Description

Provides a detailed list of all pins and their functions on the controller.

Connection Overview (Grid & Fuel Saving)

Illustrates the wiring connections for grid and fuel saving modes.

RS 485 Pin Out

Details the pin configuration for the RS 485 communication interface.

Dipswitch Settings

Explains the function and settings of the controller's dipswitches.

LED Status Indicators

Explains the meaning of the on-board LEDs for system status indication.

Software Features and Configuration

Settings Reading

Describes how to read current parameters and values from the controller.

Settings Changing

Details the procedure for modifying controller settings via the interface.

Parameter Overview

Lists and explains the available parameters for system configuration and measurement.

Output Selection Type

Explains how to configure the controller's relay outputs for different modes.

Grid Feed-in Protection

Details how to set limits for grid feed-in and manage grid consumption.

Fuel Saving Mode with Generator

Explains the fuel-saving mode and its optimization for diesel generators.

Commissioning the Hybrid Controller

First Time Power On

Provides step-by-step instructions for powering on the system for the first time.

Graphical User Interface

GUI Overview

Presents the main dashboard and system status overview displayed on the interface.

Inverter Settings Configuration

Explains how to configure and add inverters to the system via the GUI.

elgris Cloud Integration

Describes the functionality for storing and visualizing data on the elgris cloud platform.

System Settings Management

Covers general system settings, including IP address, date, time, and advanced options.

Multiple Generator Management

Details how to integrate multiple generators using elgris SMART METERS.

Example: Dual Generator with Storage

Illustrates a system setup with dual generators and optional energy storage.

PID Settings Adjustment

Manual PID Tuning

Provides a method for manually adjusting PID parameters for system stability.

Ziegler-Nichols Tuning Method

Describes the Ziegler-Nichols method for PID controller parameter tuning.

Modbus Gateway Functionality

Modbus Server Configuration

Common Model Register Mapping

Lists register mappings for the SunSpec Common Model.

WYE Meter Model Register Mapping

Lists register mappings for the WYE connect meter model.

Custom Modbus Mapping

Provides a custom MODBUS register mapping starting from address 41000.