11
CONDITIONS OF USE
Permitted use
For safety reasons the instrument must be installed and used according to the instruction provided and in
particular, under normal conditions, parts bearing dangerous voltage levels must not be accessible. The
device must be adequately protected from water and dust as per the application and must also only be
accessible via the use of tools (with the exception of the frontlet).
The device is ideally suited for use on household appliances and/or similar refrigeration equipment and has
been tested with regard to the aspects concerning European reference standards on safety.
Unpermitted use
Any other use other than that permitted is de facto prohibited. It should be noted that the relay contacts
provided are of a practical type and therefore subject to fault. Any protection devices required by product
standards or dictated by common sense due to obvious safety reasons should be applied externally.
TECHNICAL DATA
Classification: Control device (not safety) to integrate
Mounting: Panel mounting with 2-13/16” x 1-1/8” (71x29mm) drilling template
Control type: 1.B
Pollution rating: 2
Material class: IIIa
Overvoltage category class: II
Nominal impulsive voltage: 2500V
Temperature: Operating: –5 to +65°C (+23 to +149°F) - Storage: –30 to +85°C (–22 to +185°F)
Power Supply: 115Va or 230Va (
+
10% / -10%) 50/60 Hz
Consumption: 4VA max
Digital Output (relays): Please refer to the device label
Fire resistance class: D
Software class: A
NOTE: Check the power supply specified on the instrument label; for relay and power supply
capacities, contact Technical Service.