PAR. DESCRIPTION RANGE APP1 APP2 APP3 APP4 M.U.
OAO Alarm signalling delay after disabling of digital input 0 ... 10 0 0 0 0 hours
tdO Delay in door open alarm activation 0 ... 250 0 0 0 0 min
tAO Time delay for temperature alarm indication 0 ... 250 0 0 0 0 min
dAt Alarm signalling end of defrost due to timeout n/y n n n n flag
rLO External alarm locks controllers. n = does not lock; y = locks n/y n n n n flag
SA3 Probe 3 alarm Setpoint -58,0...302 0,0 0,0 0,0 0,0 °C/°F
dA3 Probe 3 alarm differential 1,0 ... 50,0 1,0 1,0 1,0 1,0 °CF
LIGHTS & DIGITAL INPUTS (“Lit” folder)
dOd
Digital input for switching off utilities. 0=disabled;
1=disables fans; 2=disables the compressor; 3=disables fans and compressor
0/1/2/3
0 0 0 0
num
dAd Activation delay for digital input 0 ... 255 0 0 0 0 min
dCO Compressor deactivation delay after door opened 0 ... 255 1 1 1 1 min
AuP Aux output activation when door opened. n = not linked; y = linked n/y n n y n flag
PRESSURE SWITCH (“PrE” folder)
Pen Number of errors allowed per maximum/minimum pressure switch input 0 ... 15
0 0 0 0
num
PEI Minimum/maximum pressure switch error count interval 1 ... 99 1 1 1 1 min
PEt Delay in activating compressor after pressure switch deactivation 0 ... 255 0 0 0 0 min
COMMUNICATION (“Add” folder)
PtS Communication protocol selection. t = Televis; d = Modbus t/d t t t t flag
dEA Index of the device inside the family (valid values from 0 to 14) 0 ... 14 0 0 0 0 num
FAA Device family - valid values from 0 to 14 0 ... 14 0 0 0 0 num
Pty Modbus parity bit. n = none; E = even; o = odd n/E/o n n n n num
StP Modbus stop bit 1b/2b 1b 1b 1b 1b flag
DISPLAY (“diS” folder)
LOC
Basic commands modification lock. It is still possible to enter parameter programming
mode and modify them. y = yes; n = no
n/y
n n n n
flag
PS1 PAssword1: if PS1≠0 is the access key to User parameters 0 ... 250 0 0 0 0 num
PS2 PAssword2: if PS2≠0 is the access key to Installer parameters 0 ... 250 15 15 15 15 num
ndt Display with decimal point. y = yes; n = no n/y y y y y flag