Manual R1140-X0-ST-EN Release: 1.06 © Elotech GmbH Page 9/24
SEn Sensor selection P1 °C Pt 100, -50,0...100,0 °C
P1 °F Pt 100, -58,0...212,0 °F
P2 °C Pt 100, -100...200 °C
P2 °F Pt 100, -148...392 °F
P4 °C Pt 100, 0...400 °C (ex works)
P4 °F Pt 100, 32...752 °F
P8° C Pt 100, 0...800 °C
P8 °F Pt 100, 32...1472 °F
L4 °C T/C Fe-CuNi (L), 0...400 °C
L4 °F T/C Fe-CuNi (L), 32...752 °F
L8 °C T/C Fe-CuNi (L), 0...800 °C
L8 °F T/C Fe-CuNi (L), 32...1472 °F
J8 °C T/C Fe-CuNi (J), 0...800 °C
J8 °F T/C Fe-CuNi (J), 32...1472 °F
n1 °C T/C NiCr-Ni (K), 0...1200 °C
n1 °F T/C NiCr-Ni (K), 32...2192 °F
S1 °C T/C Pt10Rh-Pt (S), 0...1600 °C
S1 °F T/C Pt10Rh-Pt (S), 32...2912 °F
0-20 Current-Input 0-20mA
4-20 Current-Input 4-20mA
If the Sensor selection is changed, the following parameters will be reset and need to be re-adjusted:
Parameter „Cont“: OFF Setpoint: Measuring range buttom end
Alarm values: OFF Switch-point difference: 0
Process value offset: OFF
Lower setpoint limitation: Measuring range buttom end
Higher setpoint limitation: Measuring range top end
Softstart: OFF Softstart setpoint: OFF
Setpoint 2: OFF Setpoint ramp values: OFF