EasyManua.ls Logo

Elsea COMPACT - Description of Anomalies in the Machine

Elsea COMPACT
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manuale istruzioni LAVASCIUGA MOD. ZLA40 – ZLA40C – ZLA40CB
15. DESCRIPTION OF ANOMALIES IN THE MACHINE
15.1. Trouble Shooting
DEFECT CAUSE REMEDY
The machine will not
start.
(Led off)
- F1 fuse blown
- F2 fuse blown
- Discharged battery
- Battery connector
undone/loose
- Control e/o change F1
fuse
- Control e/o Change F2
fuse
- Charge the batteries
- Connect the terminals
The brush will not
function.
- F1 fuse blown
- F2 fuse blown
- R2 relay damaged
- Control e/o change F1
fuse
- Control e/o Change F2
fuse
- Change the R2 relay
IMPORTANT! Only use fuses of the
same make and voltage, as this could
compromise the function of the
machine.
The vacuum will not
function.
- F1 fuse blown
- F2 fuse Blown
- Problem with float
contact
- R1 relay damaged
- Control e/o Change F1
fuse
- Control e/o Change F2
fuse
- Control e/o Change
float
- Change R1 relay
IMPORTANT!!!
If after trouble shooting you still encounter problems, please contact the assitants centre
directly.
15.2. Fuses
F1___________________: 80A. (GENERAL POWER)
F2___________________: 7,5A. (COMAND PANEL)
R1___________________: 24V 40A. (SUCTION MOTOR)
R2___________________: 24V 40A. (BRUSH MOTOR)
Maximum power to the machine:
Suction Motor_______ 200W max.
Brush Motor__________480W max.
05/07/11 Rev .0.0 Lavasciuga Mod.ZLA40 – ZLA40C – ZLA40CB