Activity frequency is the minimum
number of door openings or motion
counts to indicate an active 30 minute
period in the self-learning matrix.
01 – Medium frequency
02 - High frequency
03 - Automatic
Fan set point is the temperature that if
exceeded results in the evaporator fan
running continuously even if the door is
opened.
Buzzer enable is the option to disable a
warning buzzer for alarm conditions.
Does not affect door alarms.
00 (disabled) or 01 (enabled)
Saving temperature disable is the option
to maintain the ready mode temperature
at all times.
Learning period defines 1-day or 7-day
learning period.
00 (1 day) or 01 (7 days)
Display is the option to display the
temperature or the word USE.
00 (US E) or 01
(temperature)
Marketing mode is the option to keep
the lights on at all times