Handling
Water meters are accurate measuring devices and although of robust
construction should be treated with due care. The meters should
remain within their protective packaging until the point of installation.
Storage
Storage temperatures should remain within a range of 5 to 10ºC,
avoiding direct sunlight and heat.
Installation
The meter may be connected to horizontal, vertical or inclined pipes.
The installation should comply with BS5728 or BSEN14154, according to
the appropriate meter type approval and respect all relevant local bye-
laws. Only approved sealing materials should be used for making pipe
connections. The meter should be installed in a position to ensure it is
fully flooded with clean cold water at all times, in a frost protected area.
The meter should be accessible for ease of reading and should not be
subjected to installation induced stresses or vibration. Failure to do so
may result in meter damage and leakage occurring.
Earthing caution:
National legislation and local rules in force concerning the use of water
pipes for earthing shall always be consulted and adhered to. Where
the meter installation forms part of the electrical earthing, in order to
minimise the risk to operational staff, there shall be a permanent shunt
for the water meter and its associated fittings.
To enable the meter to be removed it is recommended valves be fitted
upstream and downstream of the meter, together with a drain cock
between the meter and downstream valve.