Type | Volumetric Water Meter |
---|---|
Body Material | Brass |
Pressure Rating | PN16 |
Installation | Horizontal or Vertical |
Maximum Working Pressure | 16 bar |
MID Approval | Yes |
Pulse Output | Optional |
Application | Residential and Commercial |
Maximum Water Temperature | 90°C |
Size Range | DN15, DN20, DN25, DN32, DN40 |
Temperature Range | Cold Water: Up to 30°C, Hot Water: Up to 90°C |
Guidelines for storing meters, specifying temperature range 5-10°C and avoiding sunlight/heat.
Instructions for connecting the meter to pipes, compliance, and ensuring frost protection.
Advice on consulting rules for using water pipes for earthing and fitting a permanent shunt.
Detailed steps for installing the meter, including pipe flushing and coupling.
Steps for commissioning the meter, including expelling air and checking flow.
Procedure to follow if leaks are detected at connections after installation.
Explanation of how to read mechanical meters, differentiating cubic metres and litres.
Guide to reading electronic meter displays, including billable units and sub-units.
Description of meter display modes, such as self-checking and alert status.
Information regarding product safety and compliance with relevant regulations and standards.
Guidelines for competent installation, handling, and use of products as per engineering practice.
Information on the declaration of conformity for meters bearing the CE verification mark.
Formal declaration by Elster Water Metering Limited for V100, V110 & V200 meters.